- Compact style
- Indico style
- Indico style - inline minutes
- Indico style - numbered
- Indico style - numbered + minutes
- Indico Weeks View
JJ Savioz:
- Issues related to latency for SPS BST transmission of injection and extraction prepulses means we need to use copper cables
- The PLL capture range on thr SPS Master does not allow covering the injection plateau for ion beams in the SPS
- Timing jitter of 1nsec would be adequate/acceptable on the clocks
- Possible redesign of SPS BST message?
Javier:
- First-line responsibility for BST master systems to be clarified
- Follow-up for BST consolidation (LS2) to be made once the injectors and the LHC have started
Heiko:
- Frev changes by 10% for protons in the PS and by *2.7 for ions!
- TFID RF train valid 15->20 msec before extraction - J. Emery hs requested a cable to BWS acquisition rack (could also be done by RF and BI)
- Some question of PLL Lock to be tested by BI