Multi-channel front-end ASIC for a 3D position-sensitive detector

Not scheduled
20m
Gather.town (Online)

Gather.town

Online

Poster presentation only Front end electronics and readout Poster session 2

Speaker

Dr Giovanni Pinaroli (Brookhaven National Laboratory)

Description

Arrays of 3D position-sensitive detectors (3DPSD) operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors are suitable for gamma-ray spectrometry in many applications [1,2,3]. One detector configuration, the 3D position-sensitive virtual Frisch-grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals.
For these applications, a low-noise front-end ASIC, capable of processing bipolar signals (due to the AC-coupling of some electrodes), is needed. The ASIC can be coupled to a fast ADC in order to form a compound waveform “digitizer” capable of post-processing the analog signals and determining amplitude and timing information.
This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 x 3 or 4 x 4 element matrix in the VFG configuration [4,5]. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset [6] feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I2C communication protocol. The readout channel response has been verified using the implemented injection circuit, demonstrating linear behavior up to ~100 ke-/+ with gain of ~80 mV/fC, and up to ~200 ke-/+ with gain of ~40 mV/fC. This paper reports the first test results using radioactive sources (241Am, 137Cs, Tb(kα,kβ)), where inputs have been connected to a small PIN Si diode (size = 2 x 2 mm2, thickness = 50 um, C = ~8 pf) emulating the typical detector capacitance of the elements (5 – 10 pF) used in 3DPSD.

[1] K.S. Shah et al, IEEE Trans. Nucl. Sci., vol. 36, no. 1, pp. 19 –202, 1989.
[2] K. Hitomi et al, Nucl. Instr. and Meth. A 458, no. 1, pp. 365–369, 2001.
[3] A. Owens and A. Peacock, Nucl. Instrum. Methods, vol. A531, pp. 18–37, 2004.
[4] E. Vernon et al, Nucl. Instr. and Meth. A 940, pp. 1–11, 2019.
[5] A.E. Bolotnikov et al, Nucl. Instr. and Meth. A 954, 161036, 2020.
[6] D. De Geronimo et al, IEEE Trans Nucl. Sci., vol. 47, no. 6, pp. 1857-1867

This work has been supported by the U.S. Department of Homeland Security, Countering Weapons of Mass Destruction Office, under competitively awarded contract 70RDND18C00000024. This support does not constitute an express or implied endorsement on the part of the Government.
This abstract has been co-authored by employees of Brookhaven Science Associates, LLC under Contract No. DE-SC0012704 with the U.S. Department of Energy.

Author

Dr Giovanni Pinaroli (Brookhaven National Laboratory)

Co-authors

Dr Aleksey Bolotnikov (Brookhaven National Laboratory) Mr Alfred Jr. Dellapenna (BNL) Mr Alireza Kargar (RMD) Dr Andrea Norris (BTI) Mr Andrew J Valente (BTI) Mr Conner A. Brown (RMD) Ms Connie-Rose Deane (BNL) Mr Eric Raguzin (BNL) Mr Evan R. Weststrate (RMD) Gabriella Carini (BNL) Dr Grzegorz W. Deptuch (Brookhaven National Laboratory) Jack Fried (Brookhaven National Laboratory (US)) Dr James Christian (RMD) Dr Martin B Smith (BTI) Mr Mike Squillante (RMD) Sandeep Miryala (Brookhaven National Laboratory) Dr Sven Herrmann (Brookhaven Nation Laboratory) Dr Vamshi Manthena (Brookhaven National Laboratory)